What does a “freakish baseball pitcher” have to do with current building design, you may ask? When interviewed for the Façade Tectonics Institute’s (FTI) market barriers study, Ted Kesik, PhD, a professor at the University of Toronto and façade consultant, created an apt baseball analogy to describe the unbalanced performance of façades and HVAC systems in many of today’s buildings. He described buildings that often end up with oversized HVAC systems and poor-performing façades as “like a Major League Baseball pitcher with one freakishly muscular throwing arm and the rest of the body just flab.” Read on for more background and context.

The situation stems from the fact that building design in the U.S. is typically HVAC-driven. The FTI study identified several causes of this dynamic. These causes present systemic barriers to implementing and cost-effectiveness of high-performance fenestration and façade systems.
Façade Experts are not in the Early Design Phases
While façade engineers or contractors are not invited to the early design table, HVAC professionals often are. HVAC contractors and engineers do not have sufficient façade system knowledge and naturally steer the design through an HVAC lens.
Glaziers report that HVAC contractors give input into the façade performance in the early phases of design based on the performance their HVAC systems can achieve. When the glazing contractor or façade consultant is involved, the façade design is set with little opportunity to offer improvement suggestions. Prior design decisions make those changes harder to accommodate and less likely to be successfully implemented.

HVAC and Envelopes are Designed in Silos
The FTI research reported that “HVAC design and system sizing are typically based on worst-case scenarios without considering the potential for lowering envelope loads via new façade designs.” If an effort is made to improve the façade, independent design may have already significantly oversized the HVAC system.
Several façade designers noted that even with an improved enclosure, HVAC systems are still sized to their standard business-as-usual. This means that first-cost savings from high-performance façade systems are not generated, and HVAC systems run inefficiently at a partial load through the year. Enclosure consultants also said that mechanical engineers have told them it is “because smaller system sizes for larger buildings do not yet exist.”
In the few cases where mechanical and façade engineers collaborate in the concept phases, the increased performance of the enclosure has been successfully used to eliminate perimeter heating, reduce duct size and enable heat pumps.
Andrea Zani with Permasteelisa shared, “In a recent case study carried out with an MEP (mechanical, electrical, plumbing) engineer, we noticed that on all-electric medium-to-large size projects, being able to downsize the heat pumps can bring massive capital expense savings. In addition, if you start considering lower amounts of carbon tax spent in cities like New York City and Boston, high-performance façades become more attractive.”
The upfront cost savings can have a more impactful return on investment than the energy savings alone. However, it appears that the strategy of improving the façade to reduce or eliminate HVAC systems is not yet widely adopted by mechanical system designers—to the detriment of high-performance fenestration and façade systems.
Whoever Pays the Modeler Drives the Design
HVAC contractors often provide building energy modeling for architects as a free service. Indeed, many HVAC system manufacturers have their own building simulation software. While this primarily is used for sizing their systems, it is also often used for design, especially for supporting smaller architecture firms.
Energy modelers also do their best to support the floor-to-ceiling glass that many developers still want. However, without access to façade expertise, they are likelier to use the HVAC system to manage the enclosure’s heat gain and thermal losses rather than minimize the façade-related loads.

Inadequate Energy Modeling, Especially of the Envelope
Even with good simulation tools, the FTI report identified building energy modeling as inadequate, leading to large variations in results between professionals and a poor representation of the envelope. These are the reasons cited:
- Done at the wrong time in the design process
- Poor envelope simulation
- Poor inputs
- Insufficient expertise
For architecture firms lacking the sophistication to deploy energy modeling properly, the University of Toronto’s Kesik asserted, “They usually end up with a third-rate consultant because it’s all they can afford–and the HVAC engineers throw in the energy modeling if they are awarded the work. These amateurs overwhelm the architects with too many options, and then they appear to save the day by recommending a muscular HVAC solution. You end up with a building resembling an MLB pitcher with one freakishly muscular throwing arm and the rest of the body just flab.”
The FTI report also noted, “Educating the mechanical engineers on how to properly simulate complex façade systems is fundamental to achieving more accurate cost savings and payback.”
The façade-related design experts must be present much earlier in the design process and collaborate effectively with the HVAC experts and the building energy simulators to create the optimal design. In addition, simulation competency must be improved.
Demonstrated Solutions Include:
Envelope-first energy codes
Code changes in Massachusetts, Vancouver and London show how an envelope-first approach to codes can drive design process change.
In Massachusetts and Vancouver, the increased stringency of the building envelope requirements has made it impossible to effectively design a code-compliant building without façade experts present at the early stages.

The City of London has implemented a requirement for early planning stage documentation showing how a proposed project will achieve a 35% reduction in operational carbon emissions compared to a baseline. This requirement drives façade experts to the table in very early concept development. Since early planning approval is also when the façade aesthetic is approved, the process precludes significant changes later.
Incentives
For those who prefer the carrot instead of the stick, there are several ideas from the FTI report to encourage design teams to include façade experts early:
- Fund design charrettes focusing on the façade design early in the design process
- Offer utility rebates for high-performance façade specifications
- Fund qualified façade consultants to offer design services for owners who commit to high-performance façades
- Offer financial incentives for long service life specification, which typically involves envelope performance

Specific simulation guidelines and quality control
British Columbia’s Energy Step Code requires all projects to demonstrate compliance through building energy simulation. This solves the simulation consistency problem by implementing guidelines for building energy modeling that project teams must follow. Massachusetts has also implemented quality control mechanisms to ensure consistent simulation.
In contrast, Kesik believes there should always be a prescriptive path for architecture firms that lack the sophistication to properly deploy energy modeling.
Unique HVAC-Envelope Design Approach
A unique and innovative design approach to providing high-performance buildings with high-performance façades is offered by PAE Consulting Engineers. While PAE designs the mechanical system design, calculates the interior loads and performs the energy modeling, it relies on the architect to design the façade. PAE’s president emeritus, Paul Schwer, described the process to FTI:
- First, the design architect is asked not to design the façade until the energy simulation work has started.
- Then, a code-compliant building envelope with no HVAC system is created, and a building simulation is used to calculate the indoor temperatures at the expected exterior temperature extremes for the location.
- Then, the building envelope systems are systematically improved, and the simulation is iterated without HVAC systems until they achieve minimum and maximum internal temperatures of 50 degrees Fahrenheit, and 83 degrees Fahrenheit, respectively (human survivability targets).
PAE can use this design process to implement very small HVAC systems and utilize natural ventilation. This approach was used at the RMI Innovation Center in Colorado, which has received Zero Energy Certification from the International Living Futures Institute. The project’s electric heating system uses the equivalent energy of 15 hairdryers. The building’s heating rarely operates because of its high-performance envelope, which includes quad-pane windows.
A similar approach was applied to PAE’s International Living Building-certified headquarters in Portland, Oregon. Because of the city’s more benign climate, high-performance dual-pane windows were used on this project.

Next Steps
To change to a more balanced envelope-first approach to design, several issues must be addressed:
- Façade experts need to be active in the early design stages
- Increased collaboration is needed between mechanical and façade design professionals and subcontractors
- Improved building energy simulation quality and consistency are needed, especially for façade systems
- Greater knowledge of façade solutions and how to simulate them is needed by mechanical engineers and contractors
Increased stringency of envelope-related code provisions, well-documented simulation procedures, and appropriate enforcement will help address several of these issues–as demonstrated in Massachusetts and British Columbia. While there are still challenges in these jurisdictions, business-as-usual building envelopes and their fenestration systems perform much better. These are potential blueprints for other jurisdictions and national model codes.
If our industry wants a seat at the table, I encourage you to support proposals that increase façade performance.